This website and third-party tools we use rely on cookies for the best user experience. By selecting "I agree", you agree to cookie usage as described in our Privacy Policy.
301 posters, 50 videos, 13 topics, 13 sessions, 734 authors, 193 institutions
ePostersLive by SciGen Technologies S.A. All rights reserved.
10 - 13 June, 2026 | Miami, Florida

P115
Valve � Surgical Valves
Background: The size of the aortic annulus is closely related to surgical exposure in patients with hypertrophic obstructive cardiomyopathy (HOCM) during operation. This study aims to evaluate the clinical outcomes of a novel minimally invasive approach in patients with a small aortic root.
Methods: Patients with HOCM who underwent minimally invasive electroseptal myectomy (MESM) via a right infra-axillary incision at our center from November 2023 to August 2025 were included. Those who underwent concurrent aortic valve replacement were excluded. Aortic annulus diameter <20 mm was defined as a small aortic root. Patients were divided into two groups based on this criterion, and clinical outcomes were analyzed.
Results: A total of 426 patients were included, with a mean age of 47.0 ± 14.3 years (range 12–82 years). All procedures were successfully completed via a 4–5 cm right infra-axillary incision without conversion to sternotomy. Seventy-one patients with an aortic annulus <20 mm were assigned to the small aortic root (SAR) group. No significant differences were observed between the SAR group and the normal aortic root (NAR) group in mean aortic cross-clamp time (60.3 ± 18.8 vs. 59.1 ± 15.3 minutes, P = 0.63), cardiopulmonary bypass time (95.3 ± 25.2 vs. 94.6 ± 18.8 minutes, P = 0.81), or postoperative hospital stay (6.5 ± 1.3 vs. 6.6 ± 1.1 days, P = 0.37). Immediate extubation in the operating room was achieved in 417 patients (97.9%), including all 71 patients in the SAR group (P = 0.18). Mitral valve replacement was performed in 14 patients (3.3%). Complete relief of obstruction was achieved in all patients. The mean postoperative left ventricular outflow tract gradient was 8.3 ± 2.0 mmHg in the SAR group and 8.0 ± 1.9 mmHg in the NAR group (P = 0.16). Systolic anterior motion of the mitral valve was completely resolved. There were no in-hospital deaths or procedure-related ventricular septal defects.
Conclusion: Minimally invasive electroseptal myectomy via a right infra-axillary incision provides excellent surgical exposure even in patients with a small aortic root, with clinical outcomes comparable to those in patients with a normal aortic root.