6449

INADVERTENT SUBDURAL CATHETER PLACEMENT DURING CESAREAN SECTION DELIVERY

Part of Topic

Medically Challenging Cases

Inadvertent Subdural Catheter Placement during Cesarean Section Delivery

Arundhati Pillai B.S., B.A.1 , Venkat Tummala B.S.1 , Karen Back B.S.1 , Cheng-ting Lee M.D.1,2

1.Carle Illinois College of Medicine, University of Illinois at Urbana-Champaign, Champaign, Illinois, USA
2.Carle Foundation Hospital, Urbana, Illinois, USA
 
Introduction:
•Epidural neuraxial analgesia widely used for pain management in labor/delivery
•Rare complication = inadvertent placement of catheter into the subdural space
•Can cause subdural block – unpredictable clinical picture differing from typical epidural or subarachnoid blocks 
 
Symptoms:
•Delayed or gradual onset of anesthesia
•Extensive sensory block with minimal motor involvement
•Hypotension
•Intracranial dispersion of anesthetic à dyspnea, loss of consciousness
•Conjunctival injection
•Miosis
•Abdominal respiration
•Epidural hematoma.

Case: Pregnant woman in labor with functioning lumbar epidural catheter developed symptoms consistent with high spinal anesthesia during urgent cesarean section for category II fetal heart tracing.

 

 