A Comparison between a Conventional Multi-unit Abutment and an Adjustable-angle Multi-unit Abutment-Literature Review.

Part of Topic

Original Research

A comparison between a Conventional Multi-unit Abutment and Adjustable-angle Multi-unit Abutment-Literature Review.

Ornela Briceno Gonzalez, DDS, MSc; Yi-Cheng Lai, DDS, MS, FACP.    

Introduction

Multi-unit abutments (MUAs) support screw-retained prostheses. However, conventional designs provide only fixed angulations (0°, 17°, 30°), requiring multiple abutment selections and limiting procedural adaptability. Adjustable abutments, such as Omnibut, allow continuous correction up to 30°, reducing prosthesis misfit and enhancing procedural efficiency.This review compares their biomechanical properties, clinical use, and prosthodontic application with emphasis on angulation, adaptation, and treatment efficiency.

Materials and methods

Literature and Regulatory Review

•Conventional multi-unit abutments: Evidence was obtained from finite element analyses, stress distribution studies, and clinical reports assessing prosthesis success and biomechanical load transfer.
•Adjustable multi-unit abutments (Omnibut™): Regulatory documentation, including FDA 510(k) clearance (K242064), was reviewed regarding mechanical testing and safety evaluation.

Mechanical Properties Evaluation

•The Omnibut™ system was assessed using ISO 14801 dynamic fatigue testing, retention testing, and laboratory evaluation under simulated functional conditions.

Comparative Parameters

•Range of angulation correction.
•Abutment selection requirements and efficiency of clinical procedures.
•Prosthesis fit and stress distribution.
•Range of clinical application and prosthetic system integration.

Results

•Conventional multi-unit abutments provide a single-piece gold standard design with fixed angulations (0°, 15°–17°, 30°); greater angulation increases stress concentration in implant components and cortical bone, while requiring multiple abutment selections and complex clinical procedures.

•Adjustable multi-unit abutments (Omnibut™) employ a two-component design permitting continuous correction up to 30°, demonstrate ISO 14801 fatigue equivalence, provide stable retention, reduce abutment selection demands. However, clinical outcome evidence remains limited.

Discussion

•Adjustable abutments enable clinical adjustment, support real-time correction and broaden application in compromised bone, divergent implant placement, and full-arch rehabilitation. However, clinical performance and possible complications remain uncertain.

•The need for a proprietary prosthetic screw for the final prosthesis may increase prosthesis cost compared to a standard prosthetic screw for conventional MUA’s.

Conclusion

•Conventional MUAs provide predictable outcomes but are constrained by fixed angulations and inventory demands.
•Integration of adjustable MUAs into clinical practice may improve implant rehabilitation outcomes by uniting biomechanical reliability with prosthodontic versatility.
•Future research should further explore the adjustable-angle MUA’s clinical outcome.
 
References: 
• Albakri, A. (2024). The mechanical complications and behavior of angulated dental implant abutment systems versus conventional abutments: A narrative review. The Saudi Dental Journal, 36(10), 1072–1077. https://doi.org/10.1016/j.sdentj.2024.04.005
• Demirtaş, M., Kaya, D. I., Mohammadi, R., & Demirel, G. K. (2024). The effect of different materials and multi-unit angles in stress distribution on implant supported fixed bridges: A finite element method study. International Dental Research, 14(S1), 70–80. https://doi.org/10.5577/indentres.573
• Ibrahim, et al. (2024). A finite element analysis study on different angle correction designs for inclined implants in All-on-Four protocol. BMC Oral Health, 24, 331. https://doi.org/10.1186/s12903-024-04091-2
• Kofford, B. D., & Rudisill, C. A. (2020). Adjustable angle multi-unit abutment for dental implants (U.S. Patent No. US10779944B2). U.S. Patent and Trademark Office.
• Kofford, B. D., & Rudisill, C. A. (2022). Omnidirectional multi-unit abutment system for screw-attached dental prostheses (U.S. Patent Application No. 20220387144). U.S. Patent and Trademark Office. https://ppubs.uspto.gov/pubwebapp
• Kofford, B. D., & Rudisill, C. A. (2024). Patent issued for omnidirectional multi unit abutment system for screw-attached dental prostheses (U.S. Patent No. 12023220). U.S. Patent and Trademark Office.
• Masri, R., Driscoll, C. F., & Romberg, E. (2002). Pressure generated on a simulated oral analog by impression materials in custom trays of different designs. Journal of Prosthodontics, 11(2), 82–89. https://doi.org/10.1053/jopr.2002.126692
• Wu, A. Y.-J., Wang, J., Hsu, J.-T., Fuh, L.-J., & Huang, H.-L. (2020). Biomechanical effect of implant design on four implants supporting mandibular full-arch fixed dentures: In vitro and finite element analyses. Journal of the Formosan Medical Association, 119(1), 268–276. https://doi.org/10.1016/j.jfma.2019.02.015 • Zhang, Z., Zhang, L., Wang, X., Gu, L., & Liu, Y. (2023). Optimization of stress distribution at the bone–implant interface: A review. Biomaterials Advances, 145, 213324. https://doi.org/10.1016/j.bioadv.2023.213324