Loading...

127 posters, 2 topics, 24 sessions, 326 authors, 85 institutions

ePostersLive by SciGen Technologies S.A. All rights reserved.

2023 ACP ANNUAL SESSION

October 25-28 | San Diego, CA

2023 ACP ANNUAL SESSION banner

189

A Comparison of Morse Tapered and Sloped Shoulder Implant Connection Geometry Using Torque Angle Analysis 

Part of Topic

Original Research

Research Aims: 

To compare morse taper and sloped shoulder connections, using torque-angle signature analysis on tightening and releasing processes 


Introduction:

Preload is the predominant clamping for maintaining the implant-abutment connection

It remains unclear how the geometry of the implant-abutment interfaceaffects preload due to varied displacement between components 

Torque-angle signature analysis isneeded to evaluate the dynamics ofthe clamping system process withinthe implant-abutment screwassembly.


Materials and Methods:

-Three implants were embedded into custom dies using Type V Dental stone.

-Each die was secured onto a custom measuring device where three morse taper and three sloped shoulder abutments were connected,  a driver was lowered with a torque and angle meter attached and torqued to manufacturer specification (35 Ncm)

-Insertion and removal torque-angle signatures were obtained using a digital torque gauge with an AMK-360 angle transducer

-Torque and angle values for each specimen were measured, plotted and slopes of each group compared.


 