66 posters, 2 videos, 1 audios, 2 topics, 162 authors, 49 institutions
ePostersLive by SciGen Technologies S.A. All rights reserved.
American College of Prosthodontists - 2020 ANNUAL SESSION
November 4-7 | Virtual Meeting

20
Accuracy of Denture Base Adaptation on CAD-CAM Obturator Prosthesis
Poster Presenter
Authors
Affiliations
Part of Topic
Case Presentation
Accuracy of Denture Base Adaptation on CAD-CAM Obturator Prosthesis
Amal S. Alfaraj, BDS. John A. Levon, DDS, MS, FACP. Dean Morton, BDS, MS, FACP, Wei-Shao Lin, DDS,FACP
Indiana University, School of Dentistry
ABSTRACT
Purpose: The purpose of this report is to investigate accuracy of intaglio fit of conventional and CAD-CAM obturator prosthesis.
Methods: A master cast with a palatal defect was used for the purpose of this report. 4 stone study casts were duplicated from the master cast and each one was randomly assigned to a denture processing method. CAD-CAM group was fabricated each from a separate scan of the stone study cast and the same master cast digital design was applied. For the conventional group, the same process was repeated but was milled in wax and readapted to the corresponding study casts and processed accordingly to corresponding processing technique. Dimensional variances among virtual study casts and the intaglio surfaces of resulting obturator prostheses was computed, and the mean deviation root mean square (RMS, measured in mm) was used to estimate the consistency of 2 superimposed STL files.
Results & Conclusion: There is an apparent difference between different techniques and although results reflects that CAD-CAM techniques were promising in terms of accuracy and reproducibility however, further investigation especially in terms of sample size is needed to have more definitive results.
REFERENCES
1. Chintalacheruvu VK, Balraj RU, Putchala LS, Pachalla S. Evaluation of Three Different Processing Techniques in the Fabrication of Complete Dentures. J Int Soc Prev Community Dent 2017;7(Suppl 1):S18-S23.
2. Nogueira SS, Ogle RE, Davis EL. Comparison of accuracy between compression- and injection-molded complete dentures. J Prosthet Dent 1999;82:291-300.
3. Meng TR, Latta MA. Physical properties of four acrylic denture base resins. J Contemp Dent Pract 2005;6:93-100.