167 posters, 28 videos, 9 topics, 12 sessions, 337 authors, 160 institutions
ePostersLive by SciGen Technologies S.A. All rights reserved.
ISMICS 2023 Annual Meeting
31 May - 3 June, 2023 | Boston, MA

D17
Ventricular Fibrillation After Robotic Off-pump Left Atrial Appendage Clipping. A Coronary Spasm Event.
Poster Presenter
Authors
Affiliations
Part of Topic
Arrhythmia Surgery & Interventions
Video
Background
We present a brief case in which ventricular fibrillation (VFib) required multiple attempts of electrical defibrillation after minimally invasive, off-pump, robotic-assisted left atrial appendage (LAA) clipping.
Pre-operative Presentation
A 55-year-old male with persistent atrial fibrillation (Afib) presented with fatigue and underwent investigations for LAA clipping.
PMH: Gastrointestinal bleeding, morbid obesity (BMI =40.1 kg/m²), and end-stage renal dialysis.
Robotic Clip Application and Complications
After robotic LAA clipping the patient experienced persistent VFib refractory to multiple defibrillations. Differential diagnosis included stenosis of the circumflex coronary artery due to LAA clipping, a clot occluding the coronary arteries, or electrical R-on-T ventricular extrasystole of distinct cause.
Management
Coronary angiography demonstrated a spasm of the left anterior descending artery that resolved after intravenous nitroglycerin administration.
Conclusion
Coronary spasm is a complication of LAA clipping and a prompt diagnosis and treatment impacts clinical outcomes.