Loading...

167 posters, 28 videos, 9 topics, 12 sessions, 337 authors, 160 institutions

ePostersLive by SciGen Technologies S.A. All rights reserved.

ISMICS 2023 Annual Meeting

31 May - 3 June, 2023 | Boston, MA

ISMICS 2023 Annual Meeting banner

D08

Minimally Invasive Modified Bentall De Bonno By Right Anterior Minithoracotomy In Young Man With Device Konect Resilia®

Part of Topic

Valve - Surgical Valves

Video

Minimally Invasive Modified Bentall De Bonno Procedure By Right Anterior Minithoracotomy In Young Man With Device Konect Resilia®

Ricardo Adala Benfatti1 , Amanda Ferreira Carli Benfatti2 , Wilson Barbosa Junior2 , José Anderson Goldiano1 , Gustavo Barone Perez3

1Federal University Of Mato Grosso Do Sul, Campo Grande, Brazil, 2 Instituto De Cardiologia Campo Grande, Campo Grande, Brazil, 3Servan Anestesia, Campo Grande, Brazil.

BACKGROUND: Bicuspid aortic valve (BAV) is the most common congenital heart condition, affecting 2% of the general population. BAV is a clinically mixed disorder with a high rate of surgically relevant aortic valve and ascending aortic complications, which occur in over 35% of those affected. BAV may degenerate early and the valve may become narrowed or leaky More than 99% of aortic root aneurysm and valve replacements are performed through traditional open-heart surgery. It requires making a 10-12 inch vertical incision and splitting the breastbone to access the heart, replace the patient’s own heart valve, and mend the aneurysm. The operation is typically followed by an ICU stay and eight to 12 weeks of recovery.

METHODS: C.E.O.S, 39 years old, male, carriered bicuspid valve with important insufficiency, aortic root aneurysm (53 millimeters), functional class II, important left ventricular dilatation (74/48 mm, EF 63%, bicuspid valve with important insufficiency), submitted minimally invasive Bentall de Bonno “button technique” modified procedure by right anterior minithoracotomy with implant device Konect Resilia® number 29, CEC time 150 minutes, aortic clamp time 120 minutes, surgery time 300 minutes.

RESULTS: Patient was extubated in room surgery, no use inotropic drugs, no blood transfusion, ICU time 60 hours, hospital discharge 5º postoperative day. Echocardiography post-operative showed decreased left ventricular diameters, maintenance ejection fraction, and low gradients by biological prosthesis and aortic biological tube. The patient returns professional, and physics activities precariously

CONCLUSIONS: The correction of root aortic aneurysm and aortic valve replacement with technique Bentall e de Bono modified “button technique” with device Konect Resilia® through minimally invasive cardiac surgery by right anterior minithoracotomy is feasible and reproducible with benefits intrinsic about minimally invasive cardiac surgeries. A right anterior minithoracotomy is a surgical approach that can be an excellent alternative to a median sternotomy in selected patients. 

1.Yan TD. Mini-bentall procedure: the "French cuff" technique. Ann Thorac Surg. 2016;101(2):780-2. doi:10.1016/j. athoracsur.2015.06.092
2.Kulacoglu UK & Kaya M - Ministernotomy in Aortic Root and Arch Surgery: Early Outcomes Braz J Cardiovasc Surg 2023;38(1):15-21
3.Johnson CA Jr, Siordia JA, Robinson DA, Knight PA. Right mini-thoracotomy Bentall with traditional and automated suturing devices. Multimed Man Cardiothorac Surg. 2018 May 18;2018. doi: 10.1510/mmcts.2018.025. PMID: 29781589.
4.LaPietra A, Santana O, Pineda AM, Mihos CG, Lamelas J. Outcomes of Aortic Valve and Concomitant Ascending Aorta Replacement Performed via a Minimally Invasive Right Thoracotomy Approach. Innovations. 2014;9(5):339-342.
5.Lamelas J, LaPietra A. Right Minithoracotomy Approach for Replacement of the Ascending Aorta, Hemiarch, and Aortic Valve. Innovations. 2016;11(4):301-304.
6.DeRoo SC, Desai N, Grimm JC, Cannon B, Bavaria JE. In-Human Implantation of a Novel Biologic Valved Conduit for Aortic Root Replacement. Ann Thorac Surg. 2022 Jan;113(1):e21-e24.